(896043) - Discusses an issue that occurs where you receive an error message when you try to use Project Web Access try to modify a category on a computer that is running Project Server 2003 SP1 and Office Solution Accelerator for Six Sigma.

Search KbAlertz

Advanced Search

Receive Microsoft Knowledge Base articles by E-Mail?

Every night we scan the Microsoft Knowledge Base. If technologies you're interested in are updated, we'll send you an e-mail. You only get one e-mail a day, and only when new articles are added.

Click here to create a
FREE account
Already have an account?
[Click here to Login]











Microsoft Knowledge Base Article

This article contents is Microsoft Copyrighted material.
©2005-©2007 Microsoft Corporation. All rights reserved. Terms of Use | Trademarks

Article ID: 896043 - Last Review: July 28, 2006 - Revision: 1.4

You receive an "An error occurred while completing the operation" error message when you try to modify a category by using Office Project Web Access 2003 on a computer that is running Project Server 2003 SP1 and Office Solution Accelerator for Six Sigma

SYMPTOMS

Consider the following scenario. You install Microsoft Office Project Server 2003 Service Pack 1 (SP1) on a computer that is running Microsoft Office Project Server 2003. Then, you install and configure Microsoft Office Solution Accelerator for Six Sigma. You log on to Microsoft Office Project Web Access 2003, click Admin, click Manage Security, click a category, and then you click Modify Category. When you try to modify the category, the changes that you make to the category cannot be saved. Instead, you receive the following error message:
An error occurred while completing the operation

CAUSE

This issue occurs if the versions of the Sec_editcategory.asp and Sec_definecategory.asp files that are used by Project Server 2003 SP1 are mismatched. Office Solution Accelerator for Six Sigma overwrites certain Project Server 2003 SP1 files with the versions of the files that are included in Office Solution Accelerator for Six Sigma.

RESOLUTION

To resolve this issue, replace the Sec_editcategory.asp file and the Sec_definecategory.asp file with the correct versions that are required by Project Server 2003 SP1. You must also update the Qylibstd.sql file with the information that is required by Solution Accelerator for Six Sigma. To do this, follow these steps:
  1. Replace the Sec_editcategory.asp file and the Sec_definecategory.asp file with the correct versions that are required by Project Server 2003 SP1. To do this, follow these steps:
    1. Start Microsoft Windows Explorer.
    2. Copy the Sec_editcategory.asp and Sec_definecategory.asp files that are located in the following folder:
      Drive:\Program Files\Microsoft Office Solution Accelerator for Six Sigma\ServerBackup\Server\IIS Virtual Root\Admin
      Note Office Solution Accelerator for Six Sigma backs up the original versions of the Project Server 2003 SP1 files to this folder. If you installed Project Server 2003 SP1 before you installed Office Solution Accelerator for Six Sigma, this folder contains the versions of the files that are included in Project Server 2003 SP1.
    3. Paste the Sec_editcategory.asp file and the Sec_definecategory.asp file that you copied in step 1b to the following folder:
      Drive:\Program Files\Microsoft Office Project Server 2003\IIS Virtual Root\Admin
    4. Click Yes when you are prompted to replace the existing files.
  2. Update the Qylibstd.sql file with the information that is required by Solution Accelerator for Six Sigma. To do this, follow these steps:
    1. In Notepad, open the Qylibstd.sql file that is located in the following folder:
      Drive:\Program Files\Microsoft Office Solution Accelerator for Six Sigma\ServerBackup\Server\Bin
      Note Office Solution Accelerator for Six Sigma backs up the original versions of the Project Server 2003 SP1 files to this folder. If you installed Project Server 2003 SP1 before you installed Office Solution Accelerator for Six Sigma, this folder contains the versions of the files that are included in Project Server 2003 SP1.
    2. Add the following lines to the end of the existing text in the Qylibstd.sql file:
      400000 @MSP_WEB_SP_ADM_GETURLFORTOOLS(^0)
      450000 @MSP_WEB_SP_QRY_GetAllTasksForActionItemEditForm(^0,^1,^2)
      450001 @MSP_WEB_SP_QRY_GetAllTasksForRiskEditForm(^0,^1,^2)
      450002 @MSP_WEB_SP_QRY_GetProjectActionItem(^0)
      450003 @MSP_WEB_SP_QRY_GetProjectRisks(^0)
      450004 @MSP_WEB_SP_QRY_GetAllProjectTemplates
      450005 @MSP_WEB_SP_ADM_SecGetProjectTemplatesForCategoryID(^0)
    3. Save the updated Qylibstd.sql file to the following folder:
      Drive:\Program Files\Microsoft Office Project Server 2003\Bin
    4. Click Yes when you are prompted to replace the existing file.

MORE INFORMATION

For more information about solutions for Six Sigma management by using the Microsoft Office System, visit the following Microsoft Web site:
http://www.microsoft.com/office/showcase/sixsigma/default.mspx (http://www.microsoft.com/office/showcase/sixsigma/default.mspx)

APPLIES TO
  • Microsoft Office Project Server 2003
  • Microsoft Office Solution Accelerator for Six Sigma
Keywords: 
kberrmsg kbtshoot kbprb KB896043
       

Community Feedback System

Very often, it takes hours to solve a problem. Very often, you've looked high and low, and have tried a lot of solutions. When you finally found it, chances are, it was because someone else helped you. Here's your chance to give back. Use our community feedback tool to let others know what worked for you and what didn't.

Please also understand that the community feedback system is not warranted to be correct, it's simply a system that we've built to let people try and help each other. If something in a feedback response doesn't make sense to you, or you're not comfortable making changes that the feedback talks about (like registry edits), please consult a professional.

Thank you for using kbAlertz.com Feedback System.